Product Specification


Model Name Surakhan Digital Salinity Measuring Instrument SR-PRO 2000

Measurement Principle Measuring method of electrical conductivity

Measuring Range Measures from )% to 5.0% (Resolution 0.1%)
Degree of Accuracy 0.1% ~ 2.0% (±0.1%) / 2.1% ~ 3.0% (±0.2%) / 3.1% ~ 5.0% (±0.3%)
Power Saving Function Turns off automatically after 5 minutes
Temperature Compensation Automatic temperature compensation (1℃ ~ 99℃)
Display LCD method

Complete Function Automatic fix measurement value

Usage Environment 5℃ ~ 40℃ / max 95% R.H. non-condensing

Power 3V CR2032 Battery

Waterproof Water resistance

Size / Weight 32x168x18mm / 42g(Battery included)

Product Features



Measures salinity up to 5%

Salimeter SR-PRO 2000 allows 0.0% to 5.0% wider
salinity measurement than the salinity that is edible.


Tapping Detection System Applied

When tapped lightly, the power turns ON / OFF automatically
and after five minutes, it turns off automatically.


Automatic Temperature Compensation Function

Temperature Compensation can be measured
from low temperature to hot boiling high temperature.


Water Resistance Function

Due to its water resistance function, it is suitable for places where there is a lot of water use.
It can be used anywhere, such as the laboratories, cafeterias, restaurants
and households, and it’s also easy to wash.


Can be managed in a sanitary manner due to cap application

Since there is a sensor protection cap,
the sensor can be managed in a sanitary manner and is also portable.


Additional component of ladle type silicon

You can measure with the soup inside the ladle if you attach the ladle-shaped silicon.
Ladle-type silicon can be attached and used according to the method of use and need.

Measurement Method


1
Remove the sensor cap and check the cleanliness of the sensor area.
If the sensor is not clean, wash the sensor part with water and wipe it with a soft cloth.
2
Lightly tap the body part of the product with your hand to turn on the power.
If the power does not turn on, the battery is discharged and needs replacement.
3
Immerse the sensor. When the red LED on the middle of the front part flashes,
the salinity measurement value will appear on the screen and indicate measuring / complete / sensor cleaning.
4
Uses ladle-shaped silicon based on your preference


4
After using the product, wash the sensor part with water and neutral detergent.
5
Wipe it with a soft cloth and put on the sensor protection cap before storage.

*Reference Details for Measuring

  • When you immerse the sensor, please measure 1 ~ 2cm away from the floor and the wall, also avoid any contact with the wall or solid ingredients
  • If there is contact with a solid ingredient, the measurement error will vary.
  • Measurement of food containing a lot of oil may cause the oil film to appear on the surface of the sensor, which may indicate a lower salinity value than the actual value.
  • When the soup is being boiled, the temperature may continuously change, so measurement may be unstable.
    In that case, turn off the fire and then measure.

Battery replacement


Precautions

1. After use, wash the sensor part with water and neutral detergent, and then wipe it with a soft cloth. Do not wipe the sensor part with rough loofah because it is plated.
2. When it is immersed in boiling water, please immerse only the silicon material part and be careful not to apply high heat to the body part as much as possible.
3. Since it is water resistant, you can wash it under flowing water; however, do not completely immerse it in water.
4. Place sensor protecting silicon plug on before storage and keep it out of the reach of children.
5. Be aware of the problems that may occur due to strong impact, which can damage the product and the water resistance function.
6. Avoid storage in a place exposed to high humidity, high temperature or direct sunlight.
7. Do not disassemble or modify this product.